esb and OSB above a top-floor ceiling in a WUFI model
For the Morbach ceiling, GEWG calculated less moisture accumulation with the upper esb panel than with the OSB alternative studied. The result belongs to the modelled assembly and climate.
Which layer changes?
Below the board are 60 mm of wood fibre and a 240 mm cellulose-filled joist cavity. A variable vapour retarder, service void and plasterboard follow on the room side. The one-dimensional calculation examines the insulated bay.
Does the result transfer to housing?
The bus station study derives attic conditions from the local climate. It omits a moisture allowance discussed for housing. A residential project requires its own indoor climate and layer sequence.
Winter peaks after the model settles
- esb
- ≈ 14 M-%
- OSB
- ≈ 17 M-%
- Quantity
- Moisture content of the upper board, PDF p. 8